No Description

bach f448bf83e8 typo fix 2 years ago
readme.md f448bf83e8 typo fix 2 years ago

readme.md

proxmox post install ovh soyoustart

zfs

https://www.ma-solution.fr/ovh-soyoustart-cree-un-partition-zfs-sur-un-serveur-dedie/

systemctl stop pvestatd
systemctl stop pvedaemon
systemctl stop pve-cluster
systemctl stop corosync
systemctl stop pve-ha-crm
systemctl stop pve-ha-lrm
systemctl stop pveproxy
systemctl stop pve-manager
lsblk
umount /var/lib/vz
lsblk
lvdisplay
lvremove /dev/vg/data
cat /proc/mdstat
mdadm --misc --stop /dev/md5
# mdadm –-remove /dev/md5
# mdadm –-zero-superblock /dev/sda5
# mdadm –-zero-superblock /dev/sdb5

vérifier la conf

vim /etc/mdadm/mdadm.conf

replace
ARRAY /dev/md/md5  metadata=1.2 UUID=461c077c:881eadad:8f65ec33:4ddc17e0 name=md5
by
ARRAY <ignore> UUID=461c077c:881eadad:8f65ec33:4ddc17e0

then run update-initramfs -u

enlever le point de montage automatique

vim /etc/fstab


sh zpool create -f -o ashift=12 rpool mirror /dev/sda5 /dev/sdb5 zfs set compression=lz4 rpool zfs set atime=off rpool

systemctl enable zfs-import@rpool.service

zpool list zpool status

Organiser votre pool avec un sous volume ZFS

zfs create rpool/vz zfs list

#re-définir le point de montage local par défaut pour Proxmox : zfs set mountpoint=/var/lib/vz rpool/vz

#monter automatiquement les volumes ZFS : zfs mount -a;

zfs get mounted,canmount,mountpoint rpool/vz


sh systemctl start pvestatd systemctl start pvedaemon systemctl start pve-cluster systemctl start corosync systemctl start pve-ha-crm systemctl start pve-ha-lrm systemctl start pveproxy systemctl start pve-manager


# vzdump conf

vim /etc/vzdump.conf```

# vzdump default settings

tmpdir: /var/lib/vz
#dumpdir: DIR
#storage: STORAGE_ID
#mode: snapshot|suspend|stop
#bwlimit: KBPS
#ionice: PRI
#lockwait: MINUTES
#stopwait: MINUTES
#stdexcludes: BOOLEAN
#mailto: ADDRESSLIST
#prune-backups: keep-INTERVAL=N[,...]
#script: FILENAME
#exclude-path: PATHLIST
#pigz: N
notes-template: {{guestname}}-{{node}}

lxc setting

For version >= 6.5.x the simple approach is edit /etc/pve/nodes/ns316107/lxc/VMID.conf then enter this line:

lxc.prlimit.nofile: 150000

Then .. restart the CT.